Problem: Volume of water is insufficient to adequately siphon fixture.

Cause: Control stop is not open wide enough.

Solution: Adjust control stop for desired delivery of water volume.

Cause: Adjust control stop for desired delivery of water volume.

Solution: Replace diaphragm assembly.

Cause: Low consumption diaphragm assembly is installed on water saver/conventional fixture or urinal diaphragm assembly is installed on closet fixture.

Solution: Determine the required flush volume (see label on valve or markings on fixture). Replace diaphragm assembly or relief valve for appropriate flush volume of fixture.

Cause: Inadequate water volume or pressure is available from supply.

Solution: Increase flow rate or pressure to the valve. If gauges are not available to measure supply pressure/volume, remove Relief Valve from Diaphragm Assembly and open the Control Stop.

If the fixture siphons: Additional water volume is required. Install higher flushing volume Relief valve or diaphragm assembly or cut flow ring from guide.

If the fixture DOES NOT siphon (or a low consumption flush is required): Additional steps must be taken to increase the water pressure and/or volume at the water supply.


Flush Valve

Quick Links

Zhe jiang Kexin Industry Co., Ltd.

Add: No.388,21st Binhai Road, Jinhai Area, Wenzhou Economy Technology Development Zone, Wenzhou City, Zhenjiang, China
E-mail: 
sam@cnhaixin.com
Tel: 0086-577-85220000/85221620 
Phone: +86-15558923788

Fax: 0086-577-85223598
Skype: zjhaixin

Leave a massage
Copyright  2017 Zhe jiang Kexin Industry Co., Ltd.  All rights reserved.    XML   Sitemap                                                                             Designed by tqsh.net