Problem: Length of flush is too long (long flush) or fails to shut off.

Cause: Bypass hole (upper filter ring) of diaphragm assembly is dirty.

Solution: Remove the diaphragm assembly. disassemble the filter rings from the diaphragm, wash under running water, and reassemble. Replace as necessary.

Cause: Relief valve or diaphragm assembly is damaged.

Solution: Replace relief valve or diaphragm assembly.

Cause: Water saver/conventional diaphragm assembly is installed on low consumption fixture or closet diaphragm assembly is installed on urinal fixture.

Solution: Determine the required flush volume (see label on valve or markings on fixture). Replace diaphragm assembly or relief valve for appropriate flush volume of fixture.

Cause: Inside cover is damaged.

Solution: Install new inside cover.

Cause: Line water pressure dropped and is insufficient to close valve.

Solution: Close the control stop until pressure is restored.

Cause: Relief valve is not seated properly.

Solution: Disassemble diaphragm components (relief valve, filter rings, and diaphragm unit), wash under running water, and reassemble. Replace as necessary.


Contact Us

Add: No.388,21st Binhai Road, Jinhai Area, Wenzhou Economy Technology Development Zone, Wenzhou City, Zhenjiang, China
Tel:  0086-577-85220000
​Fax: 0086-577-85223598 
Phone: +86-15558923788
whats up:+86-13738722889
Email: haixinwj@cnhaixin.com

Leave a massage
Copyright ©  Zhe jiang Kexin Industry Co., Ltd. All Rights Reserved.  XML  SITEMAP