You are here: Home » News » Knowledge Base » Problem: Length of flush is too long (long flush) or fails to shut off.

Problem: Length of flush is too long (long flush) or fails to shut off.

Views:1     Author:Site Editor     Publish Time: 2019-04-12      Origin:Site Inquire

Problem: Length of flush is too long (long flush) or fails to shut off.

Cause: Bypass hole (upper filter ring) of diaphragm assembly is dirty.

Solution: Remove the diaphragm assembly. disassemble the filter rings from the diaphragm, wash under running water, and reassemble. Replace as necessary.

Cause: Relief valve or diaphragm assembly is damaged.

Solution: Replace relief valve or diaphragm assembly.

Cause: Water saver/conventional diaphragm assembly is installed on low consumption fixture or closet diaphragm assembly is installed on urinal fixture.

Solution: Determine the required flush volume (see label on valve or markings on fixture). Replace diaphragm assembly or relief valve for appropriate flush volume of fixture.

Cause: Inside cover is damaged.

Solution: Install new inside cover.

Cause: Line water pressure dropped and is insufficient to close valve.

Solution: Close the control stop until pressure is restored.

Cause: Relief valve is not seated properly.

Solution: Disassemble diaphragm components (relief valve, filter rings, and diaphragm unit), wash under running water, and reassemble. Replace as necessary.


Flush Valve

Quick Links

Zhe jiang Kexin Industry Co., Ltd.

Add: No.388,21st Binhai Road, Jinhai Area, Wenzhou Economy Technology Development Zone, Wenzhou City, Zhenjiang, China
E-mail: 
sam@cnhaixin.com
Tel: 0086-577-85220000/85221620 
Phone: +86-15558923788

Fax: 0086-577-85223598
Skype: zjhaixin

Leave a massage
Copyright  2017 Zhe jiang Kexin Industry Co., Ltd.  All rights reserved.    XML   Sitemap                                                                             Designed by tqsh.net