Problem: Flushometer valve closes immediately (short flush).

Cause: Worn or damaged diaphragm assembly.

Solution: Replace diaphragm assembly.

Cause: Handle assembly is damaged.

Solution: Replace handle or repair with handle repair kit.

Cause: Low consumption diaphragm assembly is installed on water saver/conventional fixture or urinal diaphragm assembly is installed on closet fixture.

Solution: Determine the required flush volume (see label on valve or markings on fixture). Replace diaphragm assembly or relief valve for appropriate flush volume of fixture.